Virtual Screening Workflow — Preparation Tab

Summary

This tab allows you to make settings for ligand preparation, which is done with LigPrep. If your ligands are already 3D structures in the appropriate ionization and tautomeric state, you can deselect the Prepare ligands option.

Preparation Tab Features

Prepare ligands option

Select this option to prepare the ligands with LigPrep.

Regularize input geometries option

Regularize the input geometries, so that ligands that are identical apart from small deviations in the atom positions are always treated the same. This option uses a conversion to unique SMILES to ensure the same atom numbering and geometry.

Remove duplicates option

When regularizing input geometries, remove any duplicates. The next three options apply when duplicates are removed.

Desalt option

Remove small molecules and ions from structures (as in LigPrep) before comparing structures for duplicates.

Neutralize option

Neutralize structures (as in LigPrep) before comparing structures for duplicates.

Merge properties option

Merge properties from duplicates. If the properties have different values, the property is converted to a string that lists the values.

Generate possible states at target pH text boxes

Generate ionization and tautomeric states that have significant probability in the given pH range. Enter the target pH and the range in the text boxes.

Using options

Select the program for generating states. Selecting Ionizer generates ionization states with the ionizer program, and tautomeric states with the tautomerizer program, separately. Selecting Epik generates ionization and tautomeric states with Epik at the same time.

Add Epik metal binding states option

Generate extra states that are suitable for binding to metals in proteins, using Epik. Only available when Epik is selected for state generation.

Remove high-energy ionization/tautomer states option

Select this option to remove ionization and tautomeric states that have high energies. These are states that are likely to have low populations at the prevailing conditions.

Obtain stereochemical information from options

These options allow you to specify the source of stereochemical information. If you have 3D structures, select 3D geometry to determine the stereochemistry from the geometry. Otherwise, select Specified 2D stereo properties, to use information from the stereochemical properties in the input file. Any stereochemical center whose chirality is not determined from this information will have its chirality varied.

Unspecified stereocenters text box

Enter the maximum number of stereoisomers to be retained by LigPrep in this text box. LigPrep generates up to 32 stereoisomers, which are then filtered to retain those with the lowest energies. Note that the LigPrep run preserves any existing chirality information in the input file, and selects starting chiralities based on the chemistry of naturally occurring steroids, fused rings and peptides.

Generate low energy ring conformations text box

Enter the maximum number of ring conformations to be generated by LigPrep in this text box.

Enhance sampling of large rings using MacroModel option

Sample conformations of 7-membered and larger rings with MacroModel after ligand preparation. These ring conformations are not sampled by LigPrep.

Related Topics


Legal Notice

File: workflows/vsw_preparation_tab.html
Last updated: 29 Apr 2013